Functionality of veterinary identification microchips following low- (0.5 tesla) and high-field (3 tesla) magnetic resonance imaging
- PMID: 23763334
- DOI: 10.1111/vru.12057
Functionality of veterinary identification microchips following low- (0.5 tesla) and high-field (3 tesla) magnetic resonance imaging
Abstract
The ability to read patient identification microchips relies on the use of radiofrequency pulses. Since radiofrequency pulses also form an integral part of the magnetic resonance imaging (MRI) process, the possibility of loss of microchip function during MRI scanning is of concern. Previous clinical trials have shown microchip function to be unaffected by MR imaging using a field strength of 1 Tesla and 1.5. As veterinary MRI scanners range widely in field strength, this study was devised to determine whether exposure to lower or higher field strengths than 1 Tesla would affect the function of different types of microchip. In a phantom study, a total of 300 International Standards Organisation (ISO)-approved microchips (100 each of three different types: ISO FDX-B 1.4 × 9 mm, ISO FDX-B 2.12 × 12 mm, ISO HDX 3.8 × 23 mm) were tested in a low field (0.5) and a high field scanner (3.0 Tesla). A total of 50 microchips of each type were tested in each scanner. The phantom was composed of a fluid-filled freezer pack onto which a plastic pillow and a cardboard strip with affixed microchips were positioned. Following an MRI scan protocol simulating a head study, all of the microchips were accurately readable. Neither 0.5 nor 3 Tesla imaging affected microchip function in this study.
Keywords: MRI; function; microchip; radiofrequency identification device; small animal.
© 2013 Veterinary Radiology & Ultrasound.
Similar articles
-
[Comparison of susceptibility artifacts generated by microchips with different geometry at 1.5 Tesla magnet resonance imaging. A phantom pilot study referring to the ASTM standard test method F2119-07].Tierarztl Prax Ausg K Kleintiere Heimtiere. 2013;41(5):289-96. Tierarztl Prax Ausg K Kleintiere Heimtiere. 2013. PMID: 24127025 German.
-
Functionality of implanted microchips following magnetic resonance imaging.J Am Vet Med Assoc. 2012 Mar 1;240(5):577-9. doi: 10.2460/javma.240.5.577. J Am Vet Med Assoc. 2012. PMID: 22332627
-
[Options for the reduction of magnetic susceptibility artifacts caused by implanted microchips in 0.5 Tesla magnetic resonance imaging].Tierarztl Prax Ausg K Kleintiere Heimtiere. 2015;43(2):83-92. doi: 10.15654/TPK-140663. Epub 2015 Mar 2. Tierarztl Prax Ausg K Kleintiere Heimtiere. 2015. PMID: 25727725 German.
-
MR imaging of epilepsy: state of the art at 1.5 T and potential of 3 T.Epileptic Disord. 2003 Mar;5(1):3-20. Epileptic Disord. 2003. PMID: 12773291 Review.
-
Perspectives and limitations of parallel MR imaging at high field strengths.Neuroimaging Clin N Am. 2006 May;16(2):311-20, xi. doi: 10.1016/j.nic.2006.02.001. Neuroimaging Clin N Am. 2006. PMID: 16731369 Review.
Cited by
-
Systematic review of MRI safety literature in relation to radiofrequency thermal injury prevention.J Med Radiat Sci. 2024 Sep;71(3):445-460. doi: 10.1002/jmrs.800. Epub 2024 Jun 27. J Med Radiat Sci. 2024. PMID: 38937923 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials