SH3DImporter: Fix walls Length attribute #18854

Merged
merged 6 commits into from
Jan 7, 2025
Merged

Conversation

rostskadat
Copy link
Contributor

As suggested in #17165 (comment) the Wall Length attribute is not properly set.

This PR aims to set that attribute to the Length attribute of the Spine of the Part::Sweep used to create the Arch::Wall.

@github-actions github-actions bot added the Mod: BIM Related to the BIM/Arch Workbench label Jan 3, 2025
@maxwxyz maxwxyz requested a review from yorikvanhavre January 4, 2025 08:19
@yorikvanhavre
Copy link
Member

Looks good! Can you look at the conflicts @rostskadat ?

@yorikvanhavre yorikvanhavre removed their request for review January 6, 2025 10:31
@rostskadat
Copy link
Contributor Author

@yorikvanhavre I have updated the branch and the pipeline seems to be ok. Would you mind checking if the change can be merged? Thanks for your help

@yorikvanhavre yorikvanhavre merged commit 049f42c into FreeCAD:main Jan 7, 2025
9 checks passed
@yorikvanhavre
Copy link
Member

Ok it worked now! Thanks!