Skip to content

Simple script to control Dell PowerEdge R720xd server fan speeds via their iDRAC using IPMITool commands.

License

Notifications You must be signed in to change notification settings

DocDrydenn/svr_fans

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

62 Commits
 
 
 
 
 
 
 
 

Repository files navigation

svr_fans.sh

Simple script to control Dell PowerEdge R720xd server fan speeds via their iDRAC using IPMITool commands.

Script will also work with the Dell PowerEdge R#10-series. (Note: Running this script on those servers will throw an error; just ignore it.)

Requirements

This script checks for the below packages. If not found, it will attempt to install them via APT.

  • IPMITools
  • NetCat

Not checked or installed via script:

  • Git (needed for the install and self-update process to work.)

Install

This script is self-updating. The self-update routine uses git commands to make the update so this script should be "installed" with the below command.

git clone https://github.com/DocDrydenn/svr_fans.git

UPDATE: If you decide not to install via a git clone, you can still use this script, however, it will just skip the update check and continue on.

Usage

./svr_fans.sh <h> <##> /full/path/config.conf

    ##                      Global FanSpeed Percentage (Optional)
                            (Number between 20 and 100)
                            (This will over-ride any speeds set in CONF)'

    /full/path/config.conf  Config file path and name

    -h or h                 Show this usage and exit.

Config

Note: Highly recommend putting your config file somewhere outside of the git clone folder. Self-Update will overwrite any changes you make to the example file.

  • Line #1 - IP Address of iDRAC
  • Line #2 - ServerName (This can be whatever you want)
  • Line #3 - iDRAC User Name
  • Line #4 - iDRAC User Password
  • Line #5 - FanSpeed Percentage

Example Config (2 Servers)

192.168.1.100 192.168.1.101
Server1 Server2
root root
12345 12345
50 50

Screenshot

svr_fans

About

Simple script to control Dell PowerEdge R720xd server fan speeds via their iDRAC using IPMITool commands.