This page discusses the many factors that determine the performance of the block storage volumes that you attach to your virtual machines (VMs). Before you begin, consider the following:
-
Persistent Disk are networked storage and generally have higher latency compared to physical disks or Local SSDs. To reach the maximum performance limits of the Persistent Disk, you must issue enough I/O requests in parallel. To check if you're using a high enough queue depth to reach your required performance levels, see I/O queue depth.
-
Make sure that your application is issuing enough I/O requests to saturate the disk. Disk saturation occurs when the CPU time during I/O requests issued to the device is very high.
For workloads that primarily involve small (from 4 KB to 16 KB) random I/O requests, the limiting performance factor is random I/O requests per second (IOPS).
For workloads that primarily involve sequential or large (256 KB to 1 MB) random I/O requests, the limiting performance factor is throughput.
Choose a storage option
You can provide several different types of block storage for your VMs to use.
When you configure a persistent disk, you can select one of the following disk types:
- Balanced persistent disks (
pd-balanced
)- An alternative to performance (pd-ssd) persistent disks
- Balance of performance and cost. For most VM shapes, except very large ones, these disks have the same maximum IOPS as SSD persistent disks and lower IOPS per GiB. This disk type offers performance levels suitable for most general-purpose applications at a price point between that of standard and performance (pd-ssd) persistent disks.
- Backed by solid-state drives (SSD).
- Performance (SSD) persistent disks (
pd-ssd
)- Suitable for enterprise applications and high-performance databases that require lower latency and more IOPS than standard persistent disks provide.
- Backed by solid-state drives (SSD).
- Standard persistent disks (
pd-standard
)- Suitable for large data processing workloads that primarily use sequential I/Os.
- Backed by standard hard disk drives (HDD).
- Extreme persistent disks (
pd-extreme
)- Offer consistently high performance for both random access workloads and bulk throughput.
- Designed for high-end database workloads.
- Allow you to provision the target IOPS.
- Backed by solid-state drives (SSD).
- Available with a limited number of machine types.
If you create a disk in the Google Cloud console, the default disk type is
pd-balanced
. If you create a disk using the gcloud CLI or the
Compute Engine API, the default disk type is pd-standard
.
Each storage option has unique performance limits that depend on the machine type and number of vCPUs in use.
Performance limits for Persistent Disk
Persistent Disk have limits for the maximum IOPS and throughput that they can sustain. There are throughput and IOPS limits per GiB and per VM. Balanced Persistent Disk and performance (SSD) Persistent Disk also offer baseline performance for sustained IOPS and throughput. Balanced Persistent Disk, performance (SSD) Persistent Disk and extreme Persistent Disk are designed for sub-millisecond latencies. Factors that affect performance include machine type, disk size, VM vCPU count, and I/O block size.
This page details the performance limits for zonal Persistent Disk and regional Persistent Disk.
For information about Google Cloud Hyperdisk performance, see Hyperdisk performance limits.
Zonal Persistent Disk
This section shows IOPS and throughput limits for zonal Persistent Disk.
IOPS limits for zonal Persistent Disk
Zonal standard PD |
Zonal balanced PD |
Zonal SSD PD |
Zonal extreme PD |
Zonal SSD PD multi-writer mode |
|
---|---|---|---|---|---|
Read IOPS per GiB | 0.75 | 6 | 30 | – | 30 |
Write IOPS per GiB | 1.5 | 6 | 30 | – | 30 |
Read IOPS per VM* | 7,500 | 80,000 | 100,000 | 120,000 | 100,000 |
Write IOPS per VM* | 15,000 | 80,000 | 100,000 | 120,000 | 100,000 |
Throughput limits for zonal Persistent Disk
The following table shows throughput limits for zonal Persistent Disk.
Persistent Disk can achieve greater performance on VMs with more vCPUs. Read Network egress caps on write throughput for more information.
Zonal standard PD |
Zonal balanced PD |
Zonal SSD PD |
Zonal extreme PD |
Zonal SSD PD multi-writer mode |
|
---|---|---|---|---|---|
Throughput per GiB (MiBps) | 0.12 | 0.28 | 0.48 | – | 0.48 |
Read throughput per VM (MiBps) | 1,200 | 1,200 | 1,200 | 4,000* | 1,200 |
Write throughput per VM (MiBps) | 400 | 1,200 | 1,200 | 3,000* | 1,200 |
Regional Persistent Disk
Like zonal Persistent Disk, regional Persistent Disk can achieve greater performance when you modify factors that can affect performance, like disk size and number of vCPUs.
This section lists IOPS and throughput limits for regional Persistent Disk. These conditions apply to the stated limits:
- Achieving the stated limits requires a VM with at least 64 vCPUs and an N2 machine type or an N1 machine type running Intel Skylake or newer. VMs using other machine types, such as N2D, will have lower performance limits.
- VMs using E2 machine types will have lower performance limits because E2 machine types support a maximum of 32 vCPUs.
- Read IOPS per VM and read throughput per VM may be lower when the disk is in unreplicated mode.
IOPS limits for regional Persistent Disk
Regional standard PD |
Regional balanced PD |
Regional SSD PD |
|
---|---|---|---|
Read IOPS per GiB | 0.75 | 6 | 30 |
Write IOPS per GiB | 1.5 | 6 | 30 |
Read IOPS per VM | 7,500 | 80,000* | 100,000# |
Write IOPS per VM | 15,000 | 60,000† | 80,000^ |
Throughput limits for regional Persistent Disk
Regional standard PD |
Regional balanced PD |
Regional SSD PD |
|
---|---|---|---|
Read throughput per VM (MB/s) | 1,200 | 1,200 | 1,200 |
Write throughput per VM (MB/s) | 200 | 600 | 1000‡ |
Sharing disks between VMs
Attaching a disk to multiple VMs in read-only mode mode or in multi-writer mode does not affect aggregate performance or cost. Each machine gets a share of the per-disk performance limit. Persistent Disk created in multi-writer mode have specific IOPS and throughput limits. To learn how to share Persistent Disk between multiple VMs, see Sharing Persistent Disk between VMs.
Persistent Disk I/O operations share a common path with network traffic within your VM's hypervisor. Therefore, if your VM has significant network traffic, the actual read bandwidth and IOPS consistency might be less than the listed maximum limits. Some variability in the performance limits is to be expected, especially when operating near the maximum IOPS limits with an I/O size of 16 KB. For a summary of bandwidth expectations, see Bandwidth summary table.
Baseline performance
Balanced Persistent Disk and SSD Persistent Disk offer baseline IOPS and throughput performance in addition to sustained per GiB performance limits. Baseline performance is the same for all disk sizes and doesn't scale based on the number of disks of the same type that are attached to a VM. For example, if you have two zonal balanced Persistent Disk attached to a VM, they share a baseline performance of 3,000 IOPS.
To calculate the maximum expected performance of a Persistent Disk type, add the disk type's baseline performance to the per GiB performance limit for the disk type, multiplied by the combined size (in GiB) of all disks of the same type:
Maximum expected performance = Baseline performance + (Per GiB performance limit
* Combined disk size in GiB).
For example, the maximum IOPS of two 1000 GiB zonal balanced Persistent Disk attached to the same VM is 15,000:
3,000 baseline performance + (6 IOPS performance limit per GiB *
2000 GiB combined disk size) = 15,000 IOPS
The following table shows the baseline performance for balanced and SSD Persistent Disk.
Zonal Persistent Disk
The following table shows the baseline sustained IOPS and throughput for zonal Persistent Disk:
Zonal balanced PD |
Zonal SSD PD |
|
---|---|---|
Baseline IOPS per VM | 3,000 | 6,000 |
Baseline Throughput (MiBps) per VM | 140 | 240 |
Regional Persistent Disk
Regional Persistent Disk are supported on only E2, N1, N2, and N2D machine type VMs. The following table shows the baseline sustained IOPS and throughput for regional Persistent Disk:
Regional balanced PD |
Regional SSD PD |
|
---|---|---|
Baseline IOPS per VM | 3,000 | 6,000 |
Baseline Throughput (MiBps) per VM | 140 | 240 |
Configure your Persistent Disk and VMs
Persistent Disk performance scales with the size of the disk and with the number of vCPUs on your VM.
Performance scales until it reaches either the limits of the disk or the limits of the VM to which the disk is attached. The machine type and the number of vCPUs on the VM determine the VM limits.
The following tables show performance limits for zonal Persistent Disk.
Performance by machine type and vCPU count for zonal Persistent Disk
The following tables show how zonal Persistent Disk performance varies according to the machine type and number of vCPUs on the VM to which the disk is attached.
A2 Ultra VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
a2-ultragpu-1g | 15,000 | 15,000 | 800 | 800 |
a2-ultragpu-2g | 20,000 | 20,000 | 1,200 | 1,200 |
a2-ultragpu-4g | 50,000 | 50,000 | 1,200 | 1,200 |
a2-ultragpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
a2-ultragpu-1g | 15,000 | 15,000 | 800 | 800 |
a2-ultragpu-2g | 25,000 | 25,000 | 1,200 | 1,200 |
a2-ultragpu-4g | 60,000 | 60,000 | 1,200 | 1,200 |
a2-ultragpu-8g | 100,000 | 100,000 | 1,200 | 1,200 |
pd-standard
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
a2-ultragpu-1g | 15,000 | 5,000 | 400 | 800 |
a2-ultragpu-2g | 15,000 | 7,500 | 400 | 1,200 |
a2-ultragpu-4g | 15,000 | 7,500 | 400 | 1,200 |
a2-ultragpu-8g | 15,000 | 7,500 | 400 | 1,200 |
A2 Standard VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
a2-highgpu-1g | 15,000 | 15,000 | 800 | 800 |
a2-highgpu-2g | 20,000 | 20,000 | 1,200 | 1,200 |
a2-highgpu-4g | 50,000 | 50,000 | 1,200 | 1,200 |
a2-highgpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
a2-megagpu-16g | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
a2-highgpu-1g | 15,000 | 15,000 | 800 | 800 |
a2-highgpu-2g | 25,000 | 25,000 | 1,200 | 1,200 |
a2-highgpu-4g | 60,000 | 60,000 | 1,200 | 1,200 |
a2-highgpu-8g | 100,000 | 100,000 | 1,200 | 1,200 |
a2-megagpu-16g | 100,000 | 100,000 | 1,200 | 1,200 |
pd-standard
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
a2-highgpu-1g | 15,000 | 5,000 | 400 | 800 |
a2-highgpu-2g | 15,000 | 7,500 | 400 | 1,200 |
a2-highgpu-4g | 15,000 | 7,500 | 400 | 1,200 |
a2-highgpu-8g | 15,000 | 7,500 | 400 | 1,200 |
a2-megagpu-16g | 15,000 | 7,500 | 400 | 1,200 |
A3 Mega VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MB/s) | Maximum read throughput (MB/s) |
---|---|---|---|---|
a3-megagpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MB/s) | Maximum read throughput (MB/s) |
---|---|---|---|---|
a3-megagpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
A3 High VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MB/s) | Maximum read throughput (MB/s) |
---|---|---|---|---|
a3-highgpu-1g | 15,000 | 15,000 | 1,200 | 1,200 |
a3-highgpu-2g | 30,000 | 30,000 | 1,200 | 1,200 |
a3-highgpu-4g | 60,000 | 60,000 | 1,200 | 1,200 |
a3-highgpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MB/s) | Maximum read throughput (MB/s) |
---|---|---|---|---|
a3-highgpu-1g | 15,000 | 15,000 | 1,200 | 1,200 |
a3-highgpu-2g | 30,000 | 30,000 | 1,200 | 1,200 |
a3-highgpu-4g | 60,000 | 60,000 | 1,200 | 1,200 |
a3-highgpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
A3 Edge VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MB/s) | Maximum read throughput (MB/s) |
---|---|---|---|---|
a3-edgegpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MB/s) | Maximum read throughput (MB/s) |
---|---|---|---|---|
a3-edgegpu-8g | 80,000 | 80,000 | 1,200 | 1,200 |
C2 VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
4 | 4,000 | 4,000 | 240 | 240 |
8 | 4,000 | 4,000 | 240 | 240 |
16 | 4,000 | 8,000 | 480 | 600 |
30 | 8,000 | 15,000 | 480 | 600 |
60 | 15,000 | 15,000 | 800 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
4 | 4,000 | 4,000 | 240 | 240 |
8 | 4,000 | 4,000 | 240 | 240 |
16 | 4,000 | 8,000 | 480 | 600 |
30 | 8,000 | 15,000 | 480 | 600 |
60 | 15,000 | 30,000 | 800 | 1,200 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
4 | 4,000 | 3,000 | 240 | 240 |
8 | 4,000 | 3,000 | 240 | 240 |
16 | 4,000 | 3,000 | 240 | 240 |
30 | 8,000 | 3,000 | 240 | 240 |
60 | 15,000 | 3,000 | 240 | 240 |
C2D VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2 | 4,590 | 4,080 | 245 | 245 |
4 | 4,590 | 4,080 | 245 | 245 |
8 | 4,590 | 4,080 | 245 | 245 |
16 | 4,590 | 8,160 | 245 | 326 |
32 | 8,160 | 15,300 | 245 | 612 |
56 | 8,160 | 15,300 | 245 | 612 |
112 | 15,300 | 30,600 | 408 | 1,224 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2 | 4,590 | 4,080 | 245 | 245 |
4 | 4,590 | 4,080 | 245 | 245 |
8 | 4,590 | 4,080 | 245 | 245 |
16 | 4,590 | 8,160 | 245 | 326 |
32 | 8,160 | 15,300 | 245 | 612 |
56 | 8,160 | 15,300 | 245 | 612 |
112 | 15,300 | 30,600 | 408 | 1,224 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2 | 4,590 | 3,060 | 245 | 245 |
4 | 4,590 | 3,060 | 245 | 245 |
8 | 4,590 | 3,060 | 245 | 245 |
16 | 4,590 | 3,060 | 245 | 245 |
32 | 8,160 | 3,060 | 245 | 245 |
56 | 8,160 | 3,060 | 245 | 245 |
112 | 15,300 | 3,060 | 245 | 245 |
C3D VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
4 | 15,000 | 15,000 | 240 | 240 |
8 | 25,000 | 25,000 | 800 | 800 |
16 | 25,000 | 25,000 | 1,200 | 1,200 |
30 | 50,000 | 50,000 | 1,200 | 1,200 |
60 | 80,000 | 80,000 | 1,200 | 1,200 |
90 | 80,000 | 80,000 | 1,200 | 1,200 |
180 | 80,000 | 80,000 | 1,200 | 1,200 |
360 | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
4 | 15,000 | 15,000 | 240 | 240 |
8 | 25,000 | 25,000 | 800 | 800 |
16 | 25,000 | 25,000 | 1,200 | 1,200 |
30 | 50,000 | 50,000 | 1,200 | 1,200 |
60 | 80,000 | 80,000 | 1,200 | 1,200 |
90 | 80,000 | 80,000 | 1,200 | 1,200 |
180 | 80,000 | 80,000 | 1,200 | 1,200 |
360 | 80,000 | 80,000 | 1,200 | 1,200 |
C3 VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
4 | 15,000 | 15,000 | 240 | 240 |
8 | 15,000 | 15,000 | 240 | 240 |
22 | 20,000 | 20,000 | 800 | 800 |
44 | 50,000 | 50,000 | 1,200 | 1,200 |
88 | 80,000 | 80,000 | 1,200 | 1,200 |
176 | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
4 | 15,000 | 15,000 | 240 | 240 |
8 | 15,000 | 15,000 | 240 | 240 |
22 | 25,000 | 25,000 | 800 | 800 |
44 | 60,000 | 60,000 | 1,200 | 1,200 |
88 | 80,000 | 80,000 | 1,200 | 1,200 |
176 | 80,000 | 80,000 | 1,200 | 1,200 |
E2 VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
e2-medium* | 10,000 | 12,000 | 200 | 200 |
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 20,000 | 20,000 | 1,000 | 1,200 |
32 or more | 50,000 | 50,000 | 1,000 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
e2-medium* | 10,000 | 12,000 | 200 | 200 |
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 25,000 | 25,000 | 1,000 | 1,200 |
32 or more | 60,000 | 60,000 | 1,000 | 1,200 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
e2-medium* | 10,000 | 1,000 | 200 | 200 |
2-7 | 15,000 | 3,000 | 240 | 240 |
8-15 | 15,000 | 5,000 | 400 | 800 |
16 or more | 15,000 | 7,500 | 400 | 1,200 |
G2 VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
g2-standard-4 | 15,000 | 15,000 | 240 | 240 |
g2-standard-8 | 15,000 | 15,000 | 800 | 800 |
g2-standard-12 | 15,000 | 15,000 | 800 | 800 |
g2-standard-16 | 20,000 | 20,000 | 1,200 | 1,200 |
g2-standard-24 | 20,000 | 20,000 | 1,200 | 1,200 |
g2-standard-32 | 50,000 | 50,000 | 1,200 | 1,200 |
g2-standard-48 | 50,000 | 50,000 | 1,200 | 1,200 |
g2-standard-96 | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
g2-standard-4 | 15,000 | 15,000 | 240 | 240 |
g2-standard-8 | 15,000 | 15,000 | 800 | 800 |
g2-standard-12 | 15,000 | 15,000 | 800 | 800 |
g2-standard-16 | 25,000 | 25,000 | 1,200 | 1,200 |
g2-standard-24 | 25,000 | 25,000 | 1,200 | 1,200 |
g2-standard-32 | 60,000 | 60,000 | 1,200 | 1,200 |
g2-standard-48 | 60,000 | 60,000 | 1,200 | 1,200 |
g2-standard-96 | 100,000 | 100,000 | 1,200 | 1,200 |
H3 VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
88 | 15,000 | 15,000 | 240 | 240 |
N1 VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 15,000 | 15,000 | 204 | 240 |
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 20,000 | 20,000 | 1,200 | 1,200 |
32-63 | 50,000 | 50,000 | 1,200 | 1,200 |
64 or more | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) | |
---|---|---|---|---|---|
1 | 15,000 | 15,000 | 204 | 240 | |
2-7 | 15,000 | 15,000 | 240 | 240 | |
8-15 | 15,000 | 15,000 | 800 | 800 | |
16-31 | 25,000 | 25,000 | 1,200 | 1,200 | |
32-63 | 60,000 | 60,000 | 1,200 | 1,200 | |
64 or more | 100,000 | 100,000 | 1,200 | 1,200 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 15,000 | Up to 3,000 | 204 | 240 |
2-7 | 15,000 | 3,000 | 240 | 240 |
8-15 | 15,000 | 5,000 | 400 | 800 |
16 or more | 15,000 | 7,500 | 400 | 1,200 |
N2 VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 20,000 | 20,000 | 1,200 | 1,200 |
32-63 | 50,000 | 50,000 | 1,200 | 1,200 |
64 or more | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 25,000 | 25,000 | 1,200 | 1,200 |
32-63 | 60,000 | 60,000 | 1,200 | 1,200 |
64 or more | 100,000 | 100,000 | 1,200 | 1,200 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2-7 | 15,000 | 3,000 | 240 | 240 |
8-15 | 15,000 | 5,000 | 400 | 800 |
16 or more | 15,000 | 7,500 | 400 | 1,200 |
pd-extreme
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
n2-standard-64 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-standard-80 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-standard-96 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-standard-128 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-highmem-64 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-highmem-80 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-highmem-96 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-highmem-128 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-highcpu-64 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-highcpu-80 | 120,000 | 120,000 | 3,000 | 4,000 |
n2-highcpu-96 | 120,000 | 120,000 | 3,000 | 4,000 |
N2 VMs with 96 or more vCPUs require the Intel Ice Lake CPU platform.
N2D VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 20,000 | 20,000 | 1,200 | 1,200 |
32-63 | 50,000 | 50,000 | 1,200 | 1,200 |
64 or more | Up to 80,000 | Up to 80,000 | 1,200 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 25,000 | 25,000 | 1,200 | 1,200 |
32-63 | 60,000 | 60,000 | 1,200 | 1,200 |
64 or more | Up to 100,000 | Up to 100,000 | 1,200 | 1,200 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
2-7 | 15,000 | 3,000 | 240 | 240 |
8-15 | 15,000 | 5,000 | 400 | 800 |
16 or more | 15,000 | 7,500 | 400 | 1,200 |
M1 VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m1-megamem-96 | 80,000 | 80,000 | 1,200 | 1,200 |
m1-ultramem-40 | 60,000 | 60,000 | 1,200 | 1,200 |
m1-ultramem-80 | 70,000 | 70,000 | 1,200 | 1,200 |
m1-ultramem-160 | 70,000 | 70,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m1-megamem-96 | 90,000 | 90,000 | 1,200 | 1,200 |
m1-ultramem-40 | 60,000 | 60,000 | 1,200 | 1,200 |
m1-ultramem-80 | 70,000 | 70,000 | 1,200 | 1,200 |
m1-ultramem-160 | 70,000 | 70,000 | 1,200 | 1,200 |
pd-standard
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m1-megamem-96 | 15,000 | 7,500 | 400 | 1,200 |
m1-ultramem-40 | 15,000 | 7,500 | 400 | 1,200 |
m1-ultramem-80 | 15,000 | 7,500 | 400 | 1,200 |
m1-ultramem-160 | 15,000 | 7,500 | 400 | 1,200 |
pd-extreme
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m1-megamem-96 | 90,000 | 90,000 | 2,200 | 2,200 |
M2 VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m2-megamem-416 | 40,000 | 40,000 | 1,200 | 1,200 |
m2-ultramem-208 | 40,000 | 40,000 | 1,200 | 1,200 |
m2-ultramem-416 | 40,000 | 40,000 | 1,200 | 1,200 |
m2-hypermem-416 | 40,000 | 40,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m2-megamem-416 | 40,000 | 40,000 | 1,200 | 1,200 |
m2-ultramem-208 | 40,000 | 40,000 | 1,200 | 1,200 |
m2-ultramem-416 | 40,000 | 40,000 | 1,200 | 1,200 |
m2-hypermem-416 | 40,000 | 40,000 | 1,200 | 1,200 |
pd-standard
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m2-megamem-416 | 15,000 | 7,500 | 400 | 1,200 |
m2-ultramem-208 | 15,000 | 7,500 | 400 | 1,200 |
m2-ultramem-416 | 15,000 | 7,500 | 400 | 1,200 |
m2-hypermem-416 | 15,000 | 7,500 | 400 | 1,200 |
pd-extreme
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m2-megamem-416 | 40,000 | 40,000 | 1,200 | 2,200 |
m2-ultramem-208 | 40,000 | 40,000 | 1,200 | 2,200 |
m2-ultramem-416 | 40,000 | 40,000 | 1,200 | 2,200 |
m2-hypermem-416 | 40,000 | 40,000 | 1,200 | 2,200 |
M3 VMs
pd-balanced
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m3-megamem-64 | 40,000 | 40,000 | 1,200 | 1,200 |
m3-megamem-128 | 80,000 | 80,000 | 1,200 | 1,200 |
m3-ultramem-32 | 40,000 | 40,000 | 1,200 | 1,200 |
m3-ultramem-64 | 40,000 | 40,000 | 1,200 | 1,200 |
m3-ultramem-128 | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m3-megamem-64 | 40,000 | 40,000 | 1,200 | 1,200 |
m3-megamem-128 | 80,000 | 80,000 | 1,200 | 1,200 |
m3-ultramem-32 | 40,000 | 40,000 | 1,200 | 1,200 |
m3-ultramem-64 | 40,000 | 40,000 | 1,200 | 1,200 |
m3-ultramem-128 | 80,000 | 80,000 | 1,200 | 1,200 |
pd-extreme
Machine type | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
m3-megamem-64 | 40,000 | 40,000 | 1,200 | 2,200 |
m3-megamem-128 | 80,000 | 80,000 | 1,700 | 2,200 |
m3-ultramem-32 | 40,000 | 40,000 | 1,200 | 2,200 |
m3-ultramem-64 | 40,000 | 40,000 | 1,200 | 2,200 |
m3-ultramem-128 | 80,000 | 80,000 | 1,700 | 2,200 |
T2D VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 15,000 | 15,000 | 204 | 240 |
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 20,000 | 20,000 | 1,200 | 1,200 |
32-60 | 50,000 | 50,000 | 1,200 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 15,000 | 15,000 | 204 | 240 |
2-7 | 15,000 | 15,000 | 240 | 240 |
8-15 | 15,000 | 15,000 | 800 | 800 |
16-31 | 25,000 | 25,000 | 1,200 | 1,200 |
32-60 | 60,000 | 60,000 | 1,200 | 1,200 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 15,000 | 3,000 | 204 | 240 |
2-7 | 15,000 | 3,000 | 240 | 240 |
8-15 | 15,000 | 5,000 | 400 | 800 |
16 or more | 15,000 | 7,500 | 400 | 1,200 |
T2A VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 20,000 | 20,000 | 204 | 240 |
2-7 | 20,000 | 20,000 | 240 | 240 |
8-15 | 25,000 | 25,000 | 800 | 800 |
16-31 | 25,000 | 25,000 | 1,200 | 1,200 |
32-47 | 60,000 | 60,000 | 1,200 | 1,200 |
48 | 80,000 | 80,000 | 1,800 | 1,800 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 20,000 | 20,000 | 204 | 240 |
2-7 | 20,000 | 20,000 | 240 | 240 |
8-15 | 25,000 | 25,000 | 800 | 800 |
16-31 | 25,000 | 25,000 | 1,200 | 1,200 |
32-47 | 60,000 | 60,000 | 1,200 | 1,200 |
48 | 80,000 | 80,000 | 1,800 | 1,800 |
pd-standard
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
1 | 15,000 | 1,000 | 204 | 240 |
2-3 | 15,000 | 2,400 | 240 | 240 |
4-7 | 15,000 | 3,000 | 240 | 240 |
8-15 | 15,000 | 5,000 | 400 | 800 |
16 or more | 15,000 | 7,500 | 400 | 1,200 |
Z3 VMs
pd-balanced
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
88 | 80,000 | 80,000 | 1,200 | 1,200 |
176 | 80,000 | 80,000 | 1,200 | 1,200 |
pd-ssd
VM vCPU count | Maximum write IOPS | Maximum read IOPS | Maximum write throughput (MiBps) | Maximum read throughput (MiBps) |
---|---|---|---|---|
88 | 100,000 | 100,000 | 1,200 | 1,200 |
176 | 100,000 | 100,000 | 1,200 | 1,200 |
Example
Consider a 1,000 GiB zonal SSD Persistent Disk attached to a VM with an N2 machine type and 4 vCPUs. The read limit based solely on the size of the disk is 36,000 IOPS (6,000 baseline IOPs + (30 IOPS per GiB * 1,000 GiB)). However, the VM has 4 vCPUs so the read limit is restricted to 15,000 IOPS.
Review performance
You can review Persistent Disk performance metrics in Cloud Monitoring, Google Cloud's integrated monitoring solution.
To learn more, see Reviewing Persistent Disk performance metrics.
Optimize disk performance
To increase disk performance, start with the following steps:
Resize your Persistent Disk to increase the per-disk IOPS and throughput limits. Persistent Disk don't have any reserved, unusable capacity, so you can use the full disk without performance degradation. However, certain file system and applications might perform worse as the disk becomes full, so you might need to consider increasing the size of your disk to avoid such situations.
Change the machine type and number of vCPUs on the VM to increase the per-VM IOPS and throughput limits.
After choosing the right disk size and machine type for your VM to resolve any performance bottlenecks, your application and operating system might still need additional tuning. See Optimizing Persistent Disk performance and Optimizing Local SSD performance.
What's next
- Benchmark your Local SSDs and Persistent Disk attached to Linux VMs.
- Optimize your Persistent Disk and Local SSD performance.
- Learn about Persistent Disk and Local SSD pricing.
- Learn how to review your project log entries using the Logs Explorer.