Notifications
You must be signed in to change notification settings - Fork 38
Issues: jmcollin78/versatile_thermostat
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Author
Label
Projects
Milestones
Assignee
Sort
Issues list
add thresholds before sending the offset calibration
enhancement
New feature or request
P1
Priority 1
#680
opened Dec 2, 2024 by
jmcollin78
[FR] Expert self-regulation config per VTherm
enhancement
New feature or request
#671
opened Nov 29, 2024 by
0verEngineer
In beta 11, in configuration when unselecting valve_regulation
bug
Something isn't working
developed
When development is done and tested
P1
Priority 1
#669
opened Nov 27, 2024 by
jmcollin78
TPI parameters are not set when creating a new over_climate with valve regulation - 6.8.0Beta9
bug
Something isn't working
not reproduced
Not reproduced
#665
opened Nov 26, 2024 by
Dave811
Disabling auto-start/stop and the VTherm is off cause auto-start/stop
bug
Something isn't working
P1
Priority 1
#662
opened Nov 25, 2024 by
jmcollin78
central boiler doesn't work anymore woth 6.8.0beta
bug
Something isn't working
developed
When development is done and tested
P1
Priority 1
#661
opened Nov 24, 2024 by
jmcollin78
Add support for Opentherm?
enhancement
New feature or request
need PR
Interesting improvements that could be easily done with a PR.
#660
opened Nov 24, 2024 by
GravitySandwichh
The list of valve seems incorrect + add Sonoff installation informations in README.
bug
Something isn't working
developed
When development is done and tested
P1
Priority 1
#656
opened Nov 21, 2024 by
jmcollin78
Combine motion detection and presence detection
developed
When development is done and tested
enhancement
New feature or request
P1
Priority 1
#655
opened Nov 21, 2024 by
jmcollin78
thermostat_over_valve
the target temperature is already reached by a few degrees, but VT keeps the valve opening at 100% and heats way too much.
question
#654
opened Nov 21, 2024 by
jmcollin78
A VTherm manually turned off can be restart by auto-start/stop feature
bug
Something isn't working
developed
When development is done and tested
P1
Priority 1
#653
opened Nov 17, 2024 by
jmcollin78
missing documentation: "follow underlying temp change"
documentation
Improvements or additions to documentation
#650
opened Nov 17, 2024 by
maia
[Feature request] Add native support of Sonoff TRVZB valve in VTherm
#645
opened Nov 16, 2024 by
jmcollin78
In auto-start/stop with a Slow level, the device turn on, a few minutes after it turns off.
bug
Something isn't working
P1
Priority 1
#625
opened Nov 11, 2024 by
jmcollin78
readme: explanation of "Use internal temperature of the underlying" missing
documentation
Improvements or additions to documentation
#598
opened Nov 2, 2024 by
maia
[Feature Request] Option to use local_temperature_calibration offset for self-regulation
enhancement
New feature or request
P1
Priority 1
#595
opened Nov 2, 2024 by
0verEngineer
Power smoothing is sometimes syunchronized
bug
Something isn't working
P1
Priority 1
#360
opened Jan 23, 2024 by
jmcollin78
Combine Motion and presence feature: when no motion use Eco or Eco_away preset depending of the presence state.
enhancement
New feature or request
#267
opened Dec 11, 2023 by
jmcollin78
ProTip!
Add no:assignee to see everything that’s not assigned.