jambi1214
Loving the herd life
Hi all!
We just moved to a new farm and it is not going smoothly! We have about 3 acres right now split. I have sheep and a dog I am containing. I have a Parmak 6 solar charger connected to each, so 2. At previous farm did 3 strand poly wire and had.no problem with containment. Moved here and have setup the same (actually have new chargers, was prev on some low cost electric charger), and animals are.getting out left and right. I have a ground near each charger. All 3 strands hot. 1 low as low as they go and top strand above shoulders or so. Dog and lamb have gone under. Checked.wires all hot. I don't understand. Had electrician we know look and says it should be hitting hard. I was thinking of doing a galvanized wire on bottom row as may be better conductor. Wasn't sure if I can leave 2 tops strands poly wire or would that be a problem. Ground is also copper post several feet down. How else can I make this more powerful? Any other ideas? We are on a busy road and have 5 strand barbed wire behind it so no help. Also would turbo wire or a different wire be better? Is poly wire my problem? I was about to go change out bottom wire but wanted to ask someone first. Lastly I am using some tpost but mainly step ins so should and could that hold more wires? Alternating? I don't even know how to alternate ground and hot but also know them going under is the #1 problem .Animals are contained in back but have been having to get them out of road daily so urgent
@Mike CHS @Baymule @Ridgetop
We just moved to a new farm and it is not going smoothly! We have about 3 acres right now split. I have sheep and a dog I am containing. I have a Parmak 6 solar charger connected to each, so 2. At previous farm did 3 strand poly wire and had.no problem with containment. Moved here and have setup the same (actually have new chargers, was prev on some low cost electric charger), and animals are.getting out left and right. I have a ground near each charger. All 3 strands hot. 1 low as low as they go and top strand above shoulders or so. Dog and lamb have gone under. Checked.wires all hot. I don't understand. Had electrician we know look and says it should be hitting hard. I was thinking of doing a galvanized wire on bottom row as may be better conductor. Wasn't sure if I can leave 2 tops strands poly wire or would that be a problem. Ground is also copper post several feet down. How else can I make this more powerful? Any other ideas? We are on a busy road and have 5 strand barbed wire behind it so no help. Also would turbo wire or a different wire be better? Is poly wire my problem? I was about to go change out bottom wire but wanted to ask someone first. Lastly I am using some tpost but mainly step ins so should and could that hold more wires? Alternating? I don't even know how to alternate ground and hot but also know them going under is the #1 problem .Animals are contained in back but have been having to get them out of road daily so urgent
@Mike CHS @Baymule @Ridgetop
Last edited: