Manually tested on Arty A7-100 hardware on 2023-01-09, #2. Index 4 of the threshold presets tested to work. Checked on hardware:
- LCD Display (raw and formatted via button press)
- UART Printing (raw and formatted via button press)
- Accelerometer readings switching between Measurement Mode and Linked Mode
- Accelerometer data sensible when positioning PMOD ACL2
- Presets #4 Activity and #4 Inactivity (selected via button press)
- LEDs 2 and 3 sensible for Activity and Inactivity indications
Manually tested on Arty S7-25 hardware on 2023-01-09, #2. Index 4 of the threshold presets tested to work. Two times the start of Activity event was delayed or inconsistent with the movement of the PMOD ACL2. This could be a mistake in processing or mistake in observation. Program does function. Checked on hardware:
- LCD Display (raw and formatted via button press)
- UART Printing (raw and formatted via button press)
- Accelerometer readings switching between Measurement Mode and Linked Mode
- Accelerometer data sensible when positioning PMOD ACL2
- Presets #4 Activity and #4 Inactivity (selected via button press)
- LEDs 2 and 3 sensible for Activity and Inactivity indications Note that the JA and JB were swapped in the constraints versus the pictures in the informational documentation. PMOD ACL2 is actually at JA and not JB. PMOD CLS is actually at JB and not JA. The swap must have occurred after photos and before committing sources to GIT.
Verified on Arty-A7-100 hardware on 2022-01-02, #1. Index 4 of the threshold presets appears to work.
Verified on Arty-S7-25 hardware on 2022-01-02, #1. Index 4 of the threshold presets appears to work.
NO WARRANTY MIT LICENSE Copyright (c) 2020-2023 Timothy Stotts