Monitoring more than 1 hour #1021

Open
mmmccain opened this issue Jan 27, 2022 · 3 comments
Open

Monitoring more than 1 hour #1021

mmmccain opened this issue Jan 27, 2022 · 3 comments

Comments

@mmmccain
Copy link

When monitoring a system, if it is set to the last hour or last 10 seconds, it works great.

image

For 6 hours or longer, I only get spinning circles

image

@mmmccain
Copy link
Author

A little update that may assist. If I look at the high level view of "all monitored machines" the issue is not present. This appear to be employing a different mechanism, but it confirms the data is present.

image

@Eis-D-Z
Copy link
Contributor

Eis-D-Z commented Feb 2, 2022

Thank you for bringing it to our attention, we are currently looking into this bug.

@Eis-D-Z
Copy link
Contributor

Eis-D-Z commented Feb 8, 2022

The issue lies with influxdb and the changing of step. We are on it, but until this is fixed you could try using victoria metrics as the main monitoring method. To do this adding this line DEFAULT_MONITORING_METHOD = "telegraf-victoriametrics" to settings/settings.py is needed.