Code to read the VE.Direct-Protocol from serial into a value array. Uses a non-blocking read loop and does checksum verification before adding the data. Extra care has been taken to not used readByteUntil()
or any other blocking serial command that can mess with background services, especially on the ESP8266.
Extend this code with MQTT or any other protocol or service to send and/or extract the data.
At the moment the MPPT 75/10 and the 100/20 are configured in the config.h
.
Make sure the RX and TX of the VE.Direct-Protocol are connected to the corresponding pins in the setup, victronSerial
. On the NodeMCU, pins D7/D8 are used.
Every second the MPPT sends out data, this is put into the value
array. As per code the PrintValues()
function loops of the array and prints the values and keys.
The values can also be used with the macros defined, eg. value[VPV]
or value[ERR]
.
Note that the values are stored as chars, so convert to suitable types with functions like: atof()
or atoi()