** Please use our latest version FLIMPA (v1.4) **
FLIMPA is an open-source software designed for the phasor plot analysis of raw Time-Correlated Single Photon Counting (TCSPC) Fluorescence Lifetime Imaging Microscopy (FLIM) data.
To run the software, please download the executable (.exe) file. Currently, the .exe file runs only on Windows computers.
FLIMPA: A Versatile Software for Fluorescence Lifetime Imaging Microscopy Phasor Analysis, published in Analytical Chemistry
Sofia Kapsiani, Nino F Läubli, Edward N. Ward, Mona Shehata, Clemens F. Kaminski, Gabriele S. Kaminski Schierle
Molecular Neuroscience Group and Laser Analytics Group (University of Cambridge)
[FLIMPA (1.4)] [paper] user manual (PowerPoint)] [user manual (PDF)] [citation]
- Phasor plot generation and analysis
- Fluorescence lifetime and intensity map visualisation (individual per image)
- ROI selection
- Gallery plots of fluorescence lifetime and intensity maps
- Violin plot analysis
- Table of mean fluorescence lifetime values per image
FLIMPA can be easily run on Windows using the .exe file. Alternatively, you can clone the GitHub repository and run the software following these steps:
-
Download the repository
git clone https://github.com/SofiaKapsiani/FLIMPA.git cd FLIMPA -
Create and activate a virtual environment
conda create --name flimpa_env python=3.11 -y conda activate flimpa_env
-
Install the required packages
pip install -r requirements.txt
-
Run the software
python main.py
For detailed information please refer to our online user manuals (PowerPoint & PDF).
FLIMPA currently accepts .sdt, .ptu, and .tif file formats for phasor plot analysis. To ensure accurate results, a reference file with a known lifetime (such as a sample of Rhodamine 6G or Erythrosin B) is required to correct for instrumental errors.
For best results, we recommend using files with spatial dimensions up to 512 × 512. Files with spatial dimensions exceeding 1000 × 1000 can be analysed but may cause memory allocation errors in Python and significantly reduce analysis speed.
Importing
.tiffilesPlease ensure that your
.tifdata is in the format(time, x, y). When loading your data, you will be prompted to enter thebin width(in nanoseconds), which is essential for accurate analysis.If the exact bin width is unknown, FLIMPA provides an estimate option, calculated as:
(1 / (Instrument Frequency (in Hz) * Number of Bins)) * 10^9
However, this estimate may be inaccurate depending on your data acquisition settings.
For more information on handling .ptu files, please refer to slides 5 and 6 of the online user manual.
The software can be tested using the .sdt files provided in the sample_data folder. These sample data were used in our publication and involve COS-7 cells stained with SiR-tubulin, treated with 40 µM of Nocodazole. Control data are also included, consisting of images of untreated cells.
There are three different options for importing the data:
- Import raw data
- Import raw data and assign experimental conditions (e.g treated vs untreated)
- Import raw data with manually created masks (currently masks should be created using different software for example FLIMFit)
Example: Importing Raw Data and Assigning Experimental Conditions
Please note that FLIMPA currently only accepts single files and does not support the analysis of time-lapse data.
To run the phasor plot analysis, the following parameters need to be specified:
Laser Frequency(in MHz)- Upload a
Reference File Reference File Lifetime(in ns)Number of Time Bins(default: 3x3)Minimum Photon Count Threshold(optional, at least 100 p.c. per pixel recommended)Maximum Photon Count Threshold(optional)Baseline correction(selectingTruewill remove constant DC noise from the fluorescence decay curve, improving Fourier Transform analysis)% time bins (baseline corr.)(default: 3.5%, percentage of the initial time bins used for baseline correction)
Warning: If the true fluorescent signal is present in the initial time bins (due to issues like excessive .ptu file time binning or microscope settings), performing Baseline correction correction will subtract signal along with the noise, leading to inaccurate results. To ensure proper use of Baseline correction and % time bins (baseline corr.) please refer to slide 11 of our online user manual.
Example: Importing Reference file, setting minimum photon counts threshold and running the analysis
FLIMPA enables to visualisation of phasor plots from single images and combined plots from multiple samples. Additionally three different phasor visualisation options: scatter plots, histograms and contour maps.
FLIMPA also allows users to export all generated data. This includes:
- Lifetime and Intensity Maps: Exported as
.pngand raw.tiffiles. - Gallery Visualisations: Lifetime and intensity galleries exported as
.pngfiles. - Phasor Plots and Violin Plots: Saved with a transparent background.
- Statistical Data: A
.csvfile containing the mean fluorescence lifetime per image can be exported for further statistical analysis.
If you found FLIMPA helpful for your data analysis, please consider citing our work! 😊
@article{kapsiani2025flimpa,
title={FLIMPA: A versatile software for Fluorescence Lifetime Imaging Microscopy Phasor Analysis},
author={Kapsiani, Sofia and Läubli, Nino F and Ward, Edward N and Shehata, Mona and Kaminski, Clemens F and Kaminski Schierle, Gabriele S},
journal={Analytical Chemistry},
year={2025},
publisher={ACS Publications}
}





